Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(9)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37177596

RESUMO

In vivo determination of the skin's thermal properties is of growing interest. Several types of sensors are being designed and tested. In this field, we have developed a skin calorimeter for the determination of the heat flow, the heat capacity and the thermal resistance of the skin. The calorimeter calibration consists of the determination of the parameters of the model we have chosen to represent the behavior of the device. This model considers the heat capacity and the thermal resistance of the skin, which depend on the case (body zone, subject, physical state, etc.) and also have a strong time dependence. Therefore, this work includes a validation study with reference materials. Finally, it is concluded that the heat capacity determined is a function of the thermal penetration depth of the measurement characteristics. In the case of high thermal conductivity materials in which the thermal penetration is nearly total, the heat capacity obtained coincides with that of the reference material sample.


Assuntos
Temperatura Alta , Pele , Condutividade Térmica , Calibragem
2.
Sensors (Basel) ; 20(12)2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-32560551

RESUMO

A calorimetric sensor has been designed to measure the heat flow dissipated by a 2 x 2 cm2 skin surface. In this work, a non-invasive method is proposed to determine the heat capacity and thermal conductance of the area of skin where the measurement is made. The method consists of programming a linear variation of the temperature of the sensor thermostat during its application to the skin. The sensor is modelled as a two-inputs and two-outputs system. The inputs are 1) the power dissipated by the skin and transmitted by conduction to the sensor, and 2) the power dissipated in the sensor thermostat to maintain the programmed temperature. The outputs are 1) the calorimetric signal and 2) the thermostat temperature. The proposed method consists of a sensor modelling that allows the heat capacity of the element where dissipation takes place (the skin) to be identified, and the transfer functions (TF) that link the inputs and outputs are constructed from its value. These TFs allow the determination of the heat flow dissipated by the surface of the human body as a function of the temperature of the sensor thermostat. Furthermore, as this variation in heat flow is linear, we define and determine an equivalent thermal resistance of the skin in the measured area. The method is validated with a simulation and with experimental measurements on the surface of the human body.


Assuntos
Regulação da Temperatura Corporal , Calorimetria/instrumentação , Temperatura Alta , Temperatura Cutânea , Adulto , Humanos , Masculino , Pessoa de Meia-Idade
3.
Sensors (Basel) ; 17(12)2017 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-29182567

RESUMO

The accuracy of the direct and local measurements of the heat power dissipated by the surface of the human body, using a calorimetry minisensor, is directly related to the calibration rigor of the sensor and the correct interpretation of the experimental results. For this, it is necessary to know the characteristics of the body's local heat dissipation. When the sensor is placed on the surface of the human body, the body reacts until a steady state is reached. We propose a mathematical model that represents the rate of heat flow at a given location on the surface of a human body by the sum of a series of exponentials: W(t) = A0 + ∑Aiexp(-t/τi). In this way, transient and steady states of heat dissipation can be interpreted. This hypothesis has been tested by simulating the operation of the sensor. At the steady state, the power detected in the measurement area (4 cm²) varies depending on the sensor's thermostat temperature, as well as the physical state of the subject. For instance, for a thermostat temperature of 24 °C, this power can vary between 100-250 mW in a healthy adult. In the transient state, two exponentials are sufficient to represent this dissipation, with 3 and 70 s being the mean values of its time constants.


Assuntos
Calorimetria , Regulação da Temperatura Corporal , Temperatura Alta , Corpo Humano , Humanos , Modelos Teóricos
4.
Sensors (Basel) ; 16(11)2016 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-27827977

RESUMO

We have developed a calorimetry sensor that can perform a local measurement of the surface heat dissipated from the human body. The operating principle is based on the law of conductive heat transfer: heat dissipated by the human body passes across a thermopile located between the individual and a thermostat. Body heat power is calculated from the signals measured by the thermopile and the amount of power dissipated across the thermostat in order to maintain a constant temperature. The first prototype we built had a detection area measuring 6 × 6 cm², while the second prototype, which is described herein, had a 2 × 2 cm² detection area. This new design offers three advantages over the initial one: (1) greater resolution and three times greater thermal sensitivity; (2) a twice as fast response; and (3) it can take measurements from smaller areas of the body. The sensor has a 5 mW resolution, but the uncertainty is greater, up to 15 mW, due to the measurement and calculation procedure. The order of magnitude of measurements made in healthy subjects ranged from 60 to 300 mW at a thermostat temperature of 28 °C and an ambient room temperature of 21 °C. The values measured by the sensor depend on the ambient temperature and the thermostat's temperature, while the power dissipated depends on the individual's metabolism and any physical and/or emotional activity.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Calorimetria/instrumentação , Calorimetria/métodos , Temperatura Alta , Corpo Humano , Humanos